HOME > UPS Manufacturer > On-Line UPS > ONL Series > 7.5/10/15KVA

ONL 7.5KS/10KS/15KS (LCD)
 

Advanced Power Protection for Enterprise Network

Features :

  • Sinewave Pulse Width Modulation (SPWM)
  • IGBT inverter design
  • Double conversion on-line system
  • Multi-microprocessor control
  • Smart RS-232 communication port
  • SNMP management capability
  • Wide Input Voltage Windows (+/-25%)
  • Pure sinewave output less than 3% THD
  • Versatile, modular design
  • Expandable battery run time
  • Generator compatible
  • Cold start (DC power on)
  • Load/Battery power meter display
  • Overload, on-line, battery status LED/LCD
  • Advanced Battery Management (ABM)
  • Automatically charging in UPS off mode
  • 20kHz SPWM high frequency inverter

TOWER MODEL (LED DISPLAY) ONL- 7500S ONL-10KS ONL-15KS
TOWER MODEL (LCD DISPLAY) ONL-7500-LCD ONL-10K-LCD ONL-15K-LCD
POWER RATING P.F.=0.8 7.5KVA/6KW 10KVA/8KW 15KVA/12KW
AC INPUT Voltage 110V SYSTEM : 82.5~137.5V 220V SYSTEM : 165 ~ 275 V 165 ~ 275 V
Frequency 50 Hz or 60 Hz +/- 5 Hz
Phase Single phase
BATTERY DC Voltage 192V 192V 192V
Back-Up
Time
Full Load 14 mins 10 mins 10 mins
Half Load 35 mins 25 mins 28 mins
Type Sealed lead acid battery, free maintenance
Protection Battery low cut-off without draining any current
Recharge Time About 8 hours to 90% after fully discharged
AC OUTPUT Frequency 50Hz / 60Hz
Voltage, phase 110 /115 / 120 / 220 / 230 / 240 V Single phase
Voltage regulation +/- 1 %
Frequency stability +/- 0.5 %
Power factor 0.8 ~ 1.0 (lagging)
Harmonic distortion < 3 % of T.H.D. at linear load
Overload detection 125% to 150% for 20 seconds, 150% for 10 cycle
EFFICIENCY Whole > 85 % > 85 % > 85 %
  > 90 % > 90 % > 90 %
TRANSFER Power Failure or Recovery 0 ms
Overload Disappear Auto transfer to UPS
UPS to Bypass or vice versa 0 ms
NOISE LEVEL 1m Distance < 60 dBA
LCD INDICATOR Status Indicate line, bypass, inv, fault, bat capacity, load capacity
ALARM Battery discharge The first warning will beep every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low condition.
UPS fault Continuous beeping sound
ENVIRONMENT Temperature 0 - 40 deg
Humidity 0 % ~ 95 % (Non condensing)
INTERFACE Dry Contact Sends AC failure and battery low signals, and receives shutdown signal
RS232 Detect power failure, Battery low, Schedule UPS on/off, AC power status display
Option Novell, SNMP, Windows NT, Windows 95/98
PHYSICAL SIZE W x D x H (mm) 350 x 641 x 1010
13.8" x 25.2" x 38.2"
WEIGHT Net Weight (Kgs) 160 (352 lb) 167 (367.4 lb) 175 (385 lb)