| Tower Model (With LCD Display) | VGD-2000 | VGD-3000 |
| 19" Rack-Mount Model | VGD-2000 -RM | VGD-3000-RM |
| INPUT | Capacity (VA) | 2000VA | 3000VA |
| Capacity (W) | 1400W | 2100W |
| Voltage | 100V/110V/115V/120V/127V | 208V/220V/230V/240V | Voltage/Range | Load Capacity | Voltage/Range | Load Capacity | 60 ~ 69V | 0 ~ 40% | 120 ~ 139V | 0 ~ 40% | 70 ~ 79V | 0 ~ 70% | 140 ~ 159V | 0 ~ 70% | 80 ~ 144V | 0 ~ 100% | 160 ~ 276V | 0 ~ 100% |
|
| Frequency | 50 / 60 Hz Auto Sensing |
| OUTPUT | Voltage (on battery) | 100V, 110V, 120V, 127V or 208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage) |
| Frequency (on battery) | 50 / 60 Hz +/-0.5% |
| Transfer Time | 0 ms |
| Overload Recovery | Auto transfer to UPS |
| High Efficiency Mode (AC to AC) | > 95 % |
| UPS Green Mode | Energy saving function (No Load Shutdown) |
| UPS Design Technology | On-Line / Fully digitized microprocessor controlled |
| Output Wave Form | Sinewave |
| Harmonic Distortion | < 3% of T.H.D. at linear load |
| Crest Factor | 3 : 1 |
| PROTECTION & FILTERING | Surge Protection | 120V (IEEE C62.41) / 230V (IEEEC61000-4-5 level 3) |
| Overload Protection | 125% for 1 minute and 150% for 10 seconds |
| Short Circuit | UPS output cut off immediately or input fuse protection |
SYSTEM DISPLAY / WARNING | Visual Display (LED Model) | UPS on(green), line-mode(green), battery mode(yellow), bypass(yellow), fault(red) |
| Visual Display (LCD Model) | Input / output voltage, input / output frequency, on-line mode, back up mode, battery capacity, load level |
| Audible Alarm (Battery Back-Up) | Beep every 5 sec |
| UPS Fault | Continuous beeping sound and LCD display |
| Communication | RS-232 Serial Port and USB |
| BATTERY | Type | Sealed, maintenance-free lead acid batteries |
| DC Voltage (V) Battery (Tower ) | 72V / 12V7.2AH x 6 | 72V / 12V9AH x 6 |
| DC Voltage (V) Battery (1U) | None |
| DC Voltage (V) Battery (2U) | 72V / 12V7.2AH x 6 | 72V / 12V9AH x 6 |
| Typical Recharge Time to 90% Full | 4 hours |
| Management | Self-test, adjustable battery transfer points and alarm settings |
| Battery Protection | Cut off without draining any current when battery is low |
| Cold Start (DC Start) | YES |
| Back Up Time (Tower Model) | 7 mins | 6 mins |
Back Up Time (Full Load) | 7 mins | 6 mins |
Back Up Time (Half Load) | 15 mins | 15 mins |
| PHYSICAL | Input lnlet | NEMA 5-15 (120V) / IEC 320 (230V) |
| Receptacles | NEMA 5-15 (120V) / IEC 320 (230V) |
Total Receptacles (UPS+Surge / Surge Only)
| 12 (120V), 8 (230V) |
Tower Dimensions lnches mm (inch) W x D x H | 225 x 425 x 360 (8.9" x 16.7" x 14.2") |
19" Rack-Mount Dimensions mm (inch)
| 428 x 635 x 84 (16.9" x 25.0" x 3.3") 2U |
Net Weight kg (lb) Tower model | 31.6 (68.4)
| 32.5 (71.5) |
Shipping Weight kg (lb) Tower Model | 33.6 (73.9) | 35.5 (78.1) |
| ENVIRONMENT | Operating Temperature | 0 - 40 deg C / 32 ~ 104 deg F |
| Storage Temperature | -20 ~ 50 deg C / -4 ~ 122 deg F |
| Altitude | 3,500 meters max |
Audible Noise (1 meter from surface) | < 40 dBA |
| Relative Humidity | 0 ~ 95% humidity, non-condensing |
| CONFORMANCE | Safety | UL 1778, CE |
| EMC (EMS / EMI) | IEC 61000-4, FCC Part 15, CISPR 22 |
| Warranty | 2 years |
| Warranty policy | Warranty policy may vary depends on region |