| MODEL |
|
IMP-1025A/AP |
IMP-1200A/AP |
IMP-1500A/AP |
IMP-2000A/AP |
| OUTPUT |
Voltage (on battery) |
Simulated sine wave
at 100V / 110V / 115V / 120V or 220V / 230V / 240V
+/- 5% |
| Frequency (on battery) |
50 or 60 Hz +/-1Hz |
| Voltage Regulation( AVR) |
AVR automatically
increase output voltage 15% above input voltage if
-9% to -25% of nominal.
AVR decrease output voltage 13% below input voltage
if +9% to +25% of nominal |
| Transfer Time |
2 / 4 milliseconds,
including detection time |
| INPUT |
Voltage |
100V / 110V / 115V
/ 120V or 220V / 230V / 240V +/- 25% at line input |
| Frequency |
50 or 60 Hz +/- 10%
(auto sensing) |
PROTECTION & FILTERING |
Spike Protection |
1050 Joules |
| Unit Input |
Breaker or fuse for
overload & short circuit protection |
| Overload Protection |
UPS automatic power
off if overload exceeds 110% of nominal at 60 seconds
and 130% at 3 seconds |
| Telephone Protection |
RJ-11 (1 in 2 out*
or 1 in 1 out) compatible jacks for telephone surge
protection. |
| Ethernet Protection* |
RJ-45 compatible
jacks for Ethernet network surge protection |
| Coaxial Protection |
F1 terminal for cable
TV/modem surge protection |
| Short Circuit |
UPS output cut off
immediately or input fuse protection |
| BATTERY |
Type |
Sealed, maintenance-free
lead acid |
| Typical Recharge Time |
6 hours (to 90% of
full capacity) |
Back-up Time
(a PC with 15" monitor) |
about 50 MINs |
about 55 Mins |
about 60 MINs |
about 65 Mins |
| Protection |
Auto discharge protection |
| PHYSICAL |
Net Weight kg (lbs) |
13.4 (28.6) |
13.4 (28.6) |
13.6 (29.95) |
14.5 (31.93) |
| Shipping Weight Kg (Ibs) |
14.8 (32.6) |
14.8 (32.6) |
15.0 (33.04) |
15.9 (35.02) |
| Dimension WxDxH (mm) |
130 x 382 x 192 (5.1"
x 15.0" x 7.6") |
| Input Inlet |
IEC 320 power inlet |
| Receptacles |
NEMA 5-15R (UPS outlets
x 4 , Convenience outlets
x 2 )
IEC 320 female appliance coupler
(UPS outlets 4 , Convenience
outlets x 1 ) |
| INTERFACE |
USB / RS-232 |
Detect battery low,
Schedule UPS on/off, AC input/output power status
display |
| ALARM |
Battery Back-up |
Slow beeping sound
(about 0.47 Hz) |
| Battery Low |
Rapid beeping sound
(about 1.824 Hz) |
| Overload |
Continuously beeping
sound |
| ENVIRONMENT |
Ambient Operation |
3,500 meters max,
elevation. 0-95% humidity non-condensing, 0-40 deg |
| Audible Noise |
<40dBA (1 meter
from surface) |
| Storage Condition |
15,000 meter max.
elevation |