HOME > UPS Manufacturer > Line Interactive UPS > King Pro > 1500/2200/3000VA

King 1500/2200/3000AP
 

Complete protection for internet computers and advanced servers.

Features :

  • Line interactive design
  • Boots and buck AVR
  • Fully digitized microprocessor controlled
  • Energy saving (UPS sleep mode)
  • 50/60 Hz frequency auto sensing
  • Cold start (DC power on)
  • Lighting and surge protection
  • Short circuit and overload protection
  • Single PCB with reliable design
  • Advanced battery management (ABM)
  • Automatically charging in UPS off mode
  • Battery replacement indicator
  • Automatic diagnostics & battery check
  • Smart RS-232 communication port
  • Tel/modem internet surge suppression
  • Hot swappable battery by users
  • Extended back up time with battery
  • AVR boost & buck LED
  • Site wiring fault LED display
  • Schedule shutdown & reboot
  • Automaticaly charging when UPS is off
  • History record of power failure events
  • Back up, on-line, battery status, power status display by software

MODEL   KIN-1500AP KIN-2200AP KIN-3000AP
CAPACITY Capacity 1500AV 2200AV 3000AV
OUTPUT Voltage
(on battery)
Simulated sine wave at 100V / 110V / 115V / 120V or 220V / 230V / 240V +/- 5%
Frequency
(on battery)
50 or 60 Hz +/-0.5Hz
Voltage Regulation( AVR) AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal.
AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal
Transfer Time 2 / 4 milliseconds, including detection time
INPUT Voltage 100V / 110V / 115V / 120V or 220V / 230V / 240V +/- 25% at line input
Frequency 50 or 60 Hz +/- 5% (auto sensing)
PROTECTION
& FILTERING
Spike Protection 320 Joules, 2ms
EMI/RFI Filter 10dB at o.15MHz, 50 dB at 30MHz
Unit Input Fuse for overload & short circuit protection
Overload Protection UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
10 Base-T Cable Port Network (UTP, RJ-45) compatible jacks
Short Circuit UPS output cut off immediately or input fuse protection
BATTERY Type Sealed, maintenance-free lead acid batteries with 3-6 years typical lifetime
Typical Recharge Time 4 hours (to 90% of full capacity)
Back-up Time
(a PC with 15" monitor)
70 - 80 mins 85 -95 mins 95 - 105 mins
Protection Automatic self-test, Discharge protection, Replace battery indicator
PHYSICAL Net Weight Kg(lbs) 15.8 (34.8) 26.2 (57.6) 29.8 (65.6)
Dimension WxDxH (mm) 130 x 382 x 201
(5.1" x 15" x 7.9")
170 x 450 x 225
(6.7" x 17.7" x 8.9")
INTERFACE RS232 Bi-directional communication port
ALARM Battery Back-up Slow beeping sound (about 0.47 Hz)
Battery Low Rapid beeping sound (about 1.824 Hz)
Overload Continuously beeping sound
ENVIRONMENT Ambient Operation 3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 ¢J
Audible Noise <40dBA (1 meter from surface)