| Tower Model (LED display)
|
ULT-700-LED |
ULT-1000-LED |
ULT-1500-LED |
ULT-2000-LED |
ULT-3000-LED |
| Tower Model (LCD display)
|
ULT-700-LCD |
ULT-1000-LCD |
ULT-1500-LCD |
ULT-2000-LCD |
ULT-3000-LCD |
| 19" Rack-mount Model
|
ULT-700-RM |
ULT-1000-RM |
ULT-1500-RM |
ULT-2000-RM |
ULT-3000-RM |
| Power Rating |
P.F.=0.7 |
700VA |
1000VA |
1500VA |
2000VA |
3000VA |
| AC INPUT |
Voltage |
100V : 76V~130V,
110V : 80V~138V, 115V : 83.5V~140V, 120V : 87V~140V
200/208V : 152V~260V, 220V : 160V~276V, 230V : 167V~280V,
240V : 174V~280V |
| Frequency |
50Hz or 60Hz +/-
3Hz |
| Phase |
Single phase |
| Power Factor |
>=0.98 |
| Battery |
DC Voltage |
24V |
36V |
48V |
72V |
96V |
| Back-Up
Time |
Full Load |
6 mins |
8 mins |
6 mins |
9 mins |
7 mins |
| Half Load |
15 mins |
22 mins |
15 mins |
25 mins |
20 mins |
| Type |
Sealed lead acid
battery, maintenance free |
| Protection |
Battery low cut-off
without draining any current |
| Recharge Time |
About 8 hours to
90% after fully discharged |
| AC OUTPUT |
Frequency |
50Hz / 60Hz (Auto
detection) |
| Voltage |
100/110/115/120V
or 200/208/220/230/240V |
| Voltage regulation |
+/- 2% |
| Frequency Stability |
+/- 0.5% |
| Power Factor |
0.7 (lagging) |
| Harmonic distortion |
< 3% of T.H.D.
at linear load |
| Overload Detection |
105% for 10 seconds
and 130% +/-10% for 300 ms (Crest factor ratio 3:1) |
| EFFICIENCY |
AC to AC |
> 85% |
| TRANSFER |
Power failure or Recovery |
0 ms |
| Overload disappear |
Auto transfer to
UPS |
| UPS to Bypass or vice
versa |
0 ms |
| NOISE LEVEL |
1m. distance19"
Rack-mount |
< 45 dBA |
< 52 dBA |
| LED |
Status |
Line input (green),
inverter output (green), bypass (yellow), fault (red) |
| LCD |
Status |
Indicate line, bypass,
inverter backup, fault, bat capacity, load capacity,
I/P voltage, I/P frequency, O/P voltage, O/P frequency,
internal temperature, fault status. |
| ALARM |
Battery discharge |
The first warning
will beep every 4 seconds to indicate battery in use.
The second warning will beep every 1 second to signal
battery low. |
| UPS Fault |
Continuous beeping
sound |
| ENVIRONMENT |
Temperature |
0 degree ~ 40 degree |
| Humidity |
0% ~ 95% (Non condensing) |
| Interface |
Dry contact |
Sends AC failure
and battery low signals, and receives shutdown signal
from computer. |
| RS232 |
Detect power failure,
Battery low, Schedule UPS on/off, AC power status
display |
| Option |
Novell, SNMP, Windows
NT |
Physical size
W x D x H mm
(inch) |
Tower model |
145 x 400 x 220 (5.7"x15.7"x8.7")
|
192 x 460 x 385 (7.6"x18.1"x15.2") |
| 19" Rack-mount
1U |
430 x 395 x 89
(16.9" x 15.5" x 3.5") |
None |
| 19" Rack-Mount
2U |
430 x 400 x 130 (16.9"
x 15.7" x 5.1") |
420 x 506 x 130
(16.9" 19.9" 5.1") |
Net Weight
Kgs (lbs) |
Tower model |
12.5 (27.5lbs) |
15 (33.0lbs) |
18 (39.6lbs) |
32 (70.4lbs) |
37 (81.4lbs) |
| 19" rack-mount |
17.5 (38.5lbs) |
20 (44.0lbs) |
25 (55.0lbs) |
28 (61.6lbs) |
32 (70.4lbs) |