HOME > UPS Manufacturer > On-Line UPS > Vanguard UPS > 700/1000/1500VA

Vanguard 700/1000/1500
 

 

 


VGD-600-1500VA-LCD
Back View

 




Front View | Back View
Rack Mount Model available (1U)
for 700VA & 1KVA Vanguard

Multi Functional LCD On-Line UPS.

15 LCD Display:
Easy viewing of UPS status from LCD panel including:

O/P VoltageO/P Load (%)Battery Charge (%)
O/P FrequencyO/P Watt (W)Temperature (°C)
I/P Voltage O/P VA Battery Pack Number
I/P Frequency O/P Current (A)Rating (A)
Battery Voltage Back Up Time (Min.)CPU Version

14 UPS parameter settings:
O/P VoltageO/P Load (%)Battery Charge (%)
O/P FrequencyO/P Watt (W)Temperature (°C)
I/P Voltage O/P VA Battery Pack Number
I/P Frequency O/P Current (A)Rating (A)
Battery Voltage Back Up Time (Min.)CPU Version


Unique Design :
- Vanguard rack mount models come in different heights such as 1U, 2U, or 3U to meet different space demands.
- Vanguard rack mount now is availabl from 700VA up to 10KVA
- Vanguard 3U rack mount model is designed to be flexible and able to fit in different spaces.
- The control panel can be adjusted 90 degree around to accommodate the UPS installation direction (vertically or horizontally)
- Remote control panel feature is designed for easy control of the UPS which is placed in the unreachable area.
- The display panel can be remove from the front panel and attached to the back panel with a cable in order to provide the wired-remote feature.
- 2 different directions of insertion slots are designed to attached with display panel providing 2 different angels to suit in different space demands.


FEATURES:

  • Cold start function (DC power on)
  • Lightning and surge protection
  • Battery replacement warning
  • Schedule shutdown & reboot
  • Hot swappable battery by user
  • Emergency Power Off function
  • Battery remain time display
  • LCD display front panel
  • Optional SNMP Card slot
  • Wide input voltage range
  • Power factor correction
  • Manual bypass setting
  • Free run mode setting
  • EMI/RFI noise filter
  • Support USB communication
  • Multiple language LCD display
  • On line output voltage selected


     

  • True on-line technology provides all power protection
  • Pure sine-wave output with less than 3% THD
  • Fully digitized microprocessor controlled
  • Short Circuit and overload protection
  • Advanced battery management (ABM)
  • Automatic battery charge in UPS off mode
  • Automatic diagnostics & battery check
  • RS-232 communication port with monitoring software
  • Network/fax/modem surge protection
  • History record of power failure events
  • UPSMON plus software monitoring
  • Extended back up time with battery pack
  • Optional Extension battery pack
  • Load segmentation receptacles controllable
  • High efficiency mode selectable
  • Fan speed auto control when loads varies

Tower Model (With LCD Display)VGD-700 VGD-1000VGD-1500
19" Rack-Mount ModelVGD-700 -RMVGD-1000-RMVGD-1500-RM
INPUTCapacity (VA)700VA1000VA1500VA
Capacity (W)490W700W1050W
Voltage
100V/110V/115V/120V/127V
208V/220V/230V/240V
Voltage/Range
Load Capacity
Voltage/Range
Load Capacity
60 ~ 69V
0 ~ 40%
120 ~ 139V
0 ~ 40%
70 ~ 79V
0 ~ 70%
140 ~ 159V
0 ~ 70%
80 ~ 144V
0 ~ 100%
160 ~ 276V
0 ~ 100%
Frequency50 / 60 Hz Auto Sensing
OUTPUTVoltage (on battery)100V, 110V, 120V, 127V or 208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage)
Frequency (on battery)50 / 60 Hz +/-0.5%
Transfer Time0 ms
Overload RecoveryAuto transfer to UPS
High Efficiency Mode (AC to AC)> 95 %
UPS Green ModeEnergy saving function (No Load Shutdown)
UPS Design TechnologyOn-Line / Fully digitized microprocessor controlled
Output Wave FormSinewave
Harmonic Distortion< 3% of T.H.D. at linear load
Crest Factor3 : 1
PROTECTION & FILTERINGSurge Protection120V (IEEE C62.41) / 230V (IEEEC61000-4-5 level 3)
Overload Protection125% for 1 minute and 150% for 10 seconds
Short CircuitUPS output cut off immediately or input fuse protection
SYSTEM
DISPLAY / WARNING
Visual Display (LED Model)UPS on(green), line-mode(green), battery mode(yellow), bypass(yellow), fault(red)
Visual Display (LCD Model)Input / output voltage, input / output frequency, on-line mode, back up mode, battery capacity, load level
Audible Alarm (Battery Back-Up)Beep every 5 sec
UPS FaultContinuous beeping sound and LCD display
CommunicationRS-232 Serial Port and USB
BATTERYTypeSealed, maintenance-free lead acid batteries
DC Voltage (V) Battery (Tower )24V / 12V7.2AH x 236V / 12V7.2AH x 336V / 12V9AH x 3
DC Voltage (V) Battery (1U)24V / 6V7.2AH x 4None
DC Voltage (V) Battery (2U)24V / 12V7.2AH x 236V / 12V7.2AH x 336V / 12V9AH x 3
Typical Recharge Time to 90% Full4 hours
ManagementSelf-test, adjustable battery transfer points and alarm settings
Battery ProtectionCut off without draining any current when battery is low
Cold Start (DC Start)YES
Back Up Time (Tower Model)7 min
Back Up Time
(Full Load)
2U* = 7 min,
1U = 7 min
2U* = 7 min,
1U = 4 min
6 min
Back Up Time
(Half Load)
2U*= 15 min,
1U = 15 min
2U*= 15 min,
1U = 10 min
15 min
PHYSICAL Input lnletNEMA 5-15 (120V) / IEC 320 (230V)
ReceptaclesNEMA 5-15 (120V) / IEC 320 (230V)
Total Receptacles
(UPS+Surge / Surge Only)
6 (120V), 4 (230V)
Tower Dimensions lnches
mm (inch) W x D x H
155 x 410 x 238
(6.0" x 16.5" x 9.4")
19" Rack-Mount Dimensions mm (inch)
428 x 525 x 44 (16.9" x 20.7" x 1.7") 1UNone
428 x 425 x 84 (16.9" x 16.7" x 3.3") 2U
Net Weight kg (lb)
Tower model
13.5 (29.7)
16.2 (35.6)17.0 (37.4)
Shipping Weight kg (lb)
Tower Model
15.5 (34.1)18.2 (40.0)19.0 (41.8)
ENVIRONMENTOperating Temperature0 - 40 deg C / 32 ~ 104 deg F
Storage Temperature-20 ~ 50 deg C / -4 ~ 122 deg F
Altitude3,500 meters max
Audible Noise
(1 meter from surface)
< 40 dBA
Relative Humidity0 ~ 95% humidity, non-condensing
CONFORMANCE SafetyUL 1778, CE
EMC (EMS / EMI)IEC 61000-4, FCC Part 15, CISPR 22
Warranty2 years
Warranty policyWarranty policy may vary depends on region